Structure Design of Shaped Charge for Requirementsof Concrete Crater Diameter
Article
Figures
Metrics
Preview PDF
Reference
Related
Cited by
Materials
Abstract:
When shaped charge penetrats into concrete, crater diameter must meet certain requirements. By using theories of shaped jet formation and crater diameter growth during jet penetrating concrete, we revealed the thresholds of the velocity and diameter of jet head, and therefore obtained the related structure parameters of top liner, so that shaped charge structure was developed. We built a 60 mm copper liner and a 142 mm Tialloy liner which followed the rules of 0.6 cal and 0.7 cal incrater diameter. respectively. Xray experiment and penetration test results showed that the parameters of jet head were consistent with the results of theoretical analysis. The incrater diameter of 60 mm shaped charge reached 36 mm, and the 142 mm one reached 100 mm. They both met the design requirements.
Guo Jian, He Yong, Xiao Qiangqiang, Huang Zhengxiang, Liu Beibei. Structure Design of Shaped Charge for Requirementsof Concrete Crater Diameter[J]. Transactions of Nanjing University of Aeronautics & Astronautics,2015,32(6):681-686